SUSEPTIBILITAS MAGNETIK SISTEM PANASBUMI NON VULKANIK DESA TERAK MENGGUNAKAN METODE GEOMAGNETIK
Keywords:
geothermal, non-volcanic, Terak, anomaly, magneticAbstract
Geothermal in Bangka Belitung islands are classified as radiogenic type of non-volcanic geothermal. Geothermal in this area was formed due to granite rocks that have been fractured, folded or faulted. Geothemal Terak has a surface temperature of 550C - 61.80C with a water discharge of 0.2 liters/second. This research aims to identify the forming rocks of geothermal system at Terak village based on magnetic field anomalies. Data acquisition was measured using a Proton Precession Magnetometer (PPM) along 2.5 km with 100 m spacing and 500 m spacing between lines. Data processing was analyzed using diurnal correction, IGRF correction, RTE (Reduce to the Equator) correction, anomaly separation using Upward Continuation. Modeling performed by applying 2D Inverse Modeling. The results indicated that the reservoir rock in Terak area with non-volcanic geothermal system was granite with susceptibility 42 x 103 - 49 x 103. The depth of the reservoir rock was partially at a depth of 30 - 125 meters above sea level and some were exposed on the surface (0 - 80 meters above sea level). Reservoir rocks are scattered in the northwest area of the study.
Downloads
Download data is not yet available.
Downloads
Published
2025-07-23
How to Cite
Kusmita, T., & Tiandho, Y. (2025). SUSEPTIBILITAS MAGNETIK SISTEM PANASBUMI NON VULKANIK DESA TERAK MENGGUNAKAN METODE GEOMAGNETIK. urnal eosaintek, 9(3). etrieved from https://journal.its.ac.id/index.php/geosaintek/article/view/6074
Issue
Section
Articles